Skip to content

Southwire 4/0-4/0-4/0 Triplex Cable

0 Reviews
SKU
ZUZARA

Southwire 4/0-4/0-4/0 Triplex CableAdditional specifications Additional specifications · Mechanical Neutral rated breaking strength 8350 lb Additional specifications · Compliance Referenced cable assembly specification ICEA S-76-474; neutral-supported power cable assemblies with weather-resistant extruded insulation rated 600 V Referenced ASTM sp...

Needs Data

Product Overview

Southwire 4/0-4/0-4/0 Triplex Cable

Additional specifications

Additional specifications · Mechanical

Neutral rated breaking strength 8350 lb

Additional specifications · Compliance

Referenced cable assembly specification ICEA S-76-474; neutral-supported power cable assemblies with weather-resistant extruded insulation rated 600 V
Referenced ASTM specifications ASTM B230, B231, B400, and B901
Specified standard ASTM B230, ASTM B231, ASTM B400, ASTM B901, ICEA S-76-474

Additional specifications · Electrical

Geometric mean radius (GMR) 0.197 ft
Inductive reactance calculation assumptions Neutral assumed to carry current; phase spacing assumes cables are touching
Inductive reactance at 60 Hz 0.041 Ω/1000 ft
Maximum phase-to-phase use voltage 600 or less V
Phase-conductor AC resistance at 75°C 0.105 Ω/1000 ft
Phase-conductor DC resistance at 25°C 0.084 Ω/1000 ft
DC resistance calculation note Includes a 1% length factor for plexing

Additional specifications · Construction

Strand-count qualification Actual strand count may differ for single-input-wire construction per ASTM B901
Insulation material Cross-linked polyethylene (XLPE)
Published phase strand count 18 strands
Published neutral strand configuration 6/1
Listed phase strand count 18 listed; actual strand count may differ for single-input-wire construction under ASTM B901 strands
Listed neutral strand configuration 6/1 listed; actual strand count may differ for single-input-wire construction under ASTM B901
Conductor stranding and grade Stranded, compressed 1350-H19 construction
Nominal phase insulation thickness 60 mil
Messenger construction ACSR neutral messenger
Phase conductor construction Stranded, compressed

Additional specifications · Operating Conditions

Maximum conductor temperature 90 °C

Additional specifications · Applications

Typical applications 120 V overhead service for street lighting, outdoor lighting, and temporary service for construction
Intended application 120 V overhead service; street lighting, outdoor lighting, and temporary service for construction

Technical Specifications

Product information and specifications for the selected item.

SKU: ZUZARA

Product Information

BrandSouthwire
MPNZUZARA
SKUZUZARA
CategoryService Entrance Cable

Key Specs

Maximum Amperage (A)315
Wire Gauge0000/3
Conductor MaterialAluminum

Ratings & Conductor

Maximum Amperage (A)315
Wire Gauge0000/3
Conductor MaterialAluminum
Neutral rated breaking strength8350 lb
Geometric mean radius (GMR)0.197 ft
Strand-count qualificationActual strand count may differ for single-input-wire construction per ASTM B901
Inductive reactance calculation assumptionsNeutral assumed to carry current; phase spacing assumes cables are touching
Maximum conductor temperature90 °C
Referenced ASTM specificationsASTM B230, B231, B400, and B901
Inductive reactance at 60 Hz0.041 Ω/1000 ft
Maximum phase-to-phase use voltage600 or less V
Published phase strand count18 strands
Published neutral strand configuration6/1
Phase-conductor AC resistance at 75°C0.105 Ω/1000 ft
Phase-conductor DC resistance at 25°C0.084 Ω/1000 ft
Listed phase strand count18 listed; actual strand count may differ for single-input-wire construction under ASTM B901 strands
Listed neutral strand configuration6/1 listed; actual strand count may differ for single-input-wire construction under ASTM B901
Conductor stranding and gradeStranded, compressed 1350-H19 construction
Messenger constructionACSR neutral messenger
DC resistance calculation noteIncludes a 1% length factor for plexing
Phase conductor constructionStranded, compressed

Cable Details

Jacket ColorBlack
Referenced cable assembly specificationICEA S-76-474; neutral-supported power cable assemblies with weather-resistant extruded insulation rated 600 V
Insulation materialCross-linked polyethylene (XLPE)
Typical applications120 V overhead service for street lighting, outdoor lighting, and temporary service for construction
Specified standardASTM B230, ASTM B231, ASTM B400, ASTM B901, ICEA S-76-474
Intended application120 V overhead service; street lighting, outdoor lighting, and temporary service for construction
Nominal phase insulation thickness60 mil

Dimensions & Weight

Length (in.)12000
Weight (lb.)786.4

Your cart

0 products 0 units

Your cart is empty.

Add products as you browse, then review them here.