Southwire 12/2 MC Hospital Grade Stranded Cable

0 Reviews
SKU
12-2 MC STR HCF-FT

Southwire 12/2 MC Hospital Grade Stranded CableAdditional specifications Additional specifications · Installation Minimum bend radius 3.7 in Hazardous-location suitability Class I Division 2; Class II Division 2; Class III Division 1 Patient-care installation conditions Install patient-care branch circuits per NEC Articles 517 and 330, with mechani...

Needs Data

Product Overview

Southwire 12/2 MC Hospital Grade Stranded Cable

Additional specifications

Additional specifications · Installation

Minimum bend radius 3.7 in
Hazardous-location suitability Class I Division 2; Class II Division 2; Class III Division 1
Patient-care installation conditions Install patient-care branch circuits per NEC Articles 517 and 330, with mechanical protection per Article 300.4

Additional specifications · Construction

Conductor strand count 19 strands
Redundant grounding path Bare 8000 series aluminum grounding/bonding conductor and armor
Binder material Mylar tape
Armor construction Green aluminum interlocked armor
Equipment grounding/bonding conductor Full-sized aluminum equipment grounding/bonding conductor
Insulated ground construction Green-insulated PVC with nylon sheath, THHN/THWN
Phase conductor insulation Polyvinyl chloride with nylon sheath, THHN/THWN

Additional specifications · Compatibility

Compatible fittings UL-listed MCI-A fittings

Additional specifications · Compliance

Environmental directive RoHS-2, European Directive 2011/65/EU
Metal-clad cable standard UL 1569 — Metal-Clad Cables
Firestop-system use listing Listed for UL 1-, 2-, and 3-hour through-penetration firestop systems
Insulated-wire standard UL 83 — Thermoplastic Insulated Wires and Cables

Additional specifications · Electrical

AC resistance at 75°C 2.063 Ω/1000 ft
UL-listed voltage rating 600 V
DC resistance at 25°C 1.662 Ω/1000 ft
Inductive reactance at 60 Hz 0.054 Ω/1000 ft
Voltage designation in product title 120/208 V

Additional specifications · Operating conditions

THHN/THWN dry temperature rating 90 °C (dry)

Additional specifications · Safety

Use restriction Use is prohibited in hazardous anesthetizing areas

Additional specifications · Fire performance

FT4 vertical-tray fire tests UL 1685 FT4 and IEEE 1202 FT4; IEEE test specified at 70,000 BTU/hr
Flame rating VW1

Technical Specifications

Product information and specifications for the selected item.

SKU: 12-2 MC STR HCF-FT

Product Information

BrandSouthwire
MPN12-2 MC STR HCF-FT
SKU12-2 MC STR HCF-FT
CategoryMC Cable & Armored Cable

Key Specs

Wire Gauge12/2
Maximum Amperage (A)30
Conductor MaterialCopper
Total Wire Length (ft.)250
Indoor/OutdoorIndoor

Electrical & Conductor

Wire Gauge12/2
Maximum Amperage (A)30
Conductor MaterialCopper
Conductor strand count19 strands
Redundant grounding pathBare 8000 series aluminum grounding/bonding conductor and armor
AC resistance at 75°C2.063 Ω/1000 ft
THHN/THWN dry temperature rating90 °C (dry)
Equipment grounding/bonding conductorFull-sized aluminum equipment grounding/bonding conductor
UL-listed voltage rating600 V
Insulated ground constructionGreen-insulated PVC with nylon sheath, THHN/THWN
Phase conductor insulationPolyvinyl chloride with nylon sheath, THHN/THWN
DC resistance at 25°C1.662 Ω/1000 ft
Inductive reactance at 60 Hz0.054 Ω/1000 ft
Voltage designation in product title120/208 V

Ratings & Features

Indoor/OutdoorIndoor
FeaturesHeat Resistant
Minimum bend radius3.7 in
Hazardous-location suitabilityClass I Division 2; Class II Division 2; Class III Division 1
Compatible fittingsUL-listed MCI-A fittings
Patient-care installation conditionsInstall patient-care branch circuits per NEC Articles 517 and 330, with mechanical protection per Article 300.4
Binder materialMylar tape
Environmental directiveRoHS-2, European Directive 2011/65/EU
Armor constructionGreen aluminum interlocked armor
Metal-clad cable standardUL 1569 — Metal-Clad Cables
Use restrictionUse is prohibited in hazardous anesthetizing areas
FT4 vertical-tray fire testsUL 1685 FT4 and IEEE 1202 FT4; IEEE test specified at 70,000 BTU/hr
Firestop-system use listingListed for UL 1-, 2-, and 3-hour through-penetration firestop systems
Insulated-wire standardUL 83 — Thermoplastic Insulated Wires and Cables
Flame ratingVW1

Length & Packaging

Total Wire Length (ft.)250

Dimensions & Weight

Height (in.)6
Width (in.)14
Length (in.)14
Weight (lb.)33.83