{"product_id":"southwire-4-0-4-0-4-0-triplex-cable","title":"Southwire 4\/0-4\/0-4\/0 Triplex Cable","description":"\u003cp\u003eSouthwire 4\/0-4\/0-4\/0 Triplex Cable\u003c\/p\u003e\u003c!-- registry-additional-specifications:start --\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eAdditional specifications\u003c\/h2\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Mechanical\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eNeutral rated breaking strength\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e8350 lb\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Compliance\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eReferenced cable assembly specification\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eICEA S-76-474; neutral-supported power cable assemblies with weather-resistant extruded insulation rated 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eReferenced ASTM specifications\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eASTM B230, B231, B400, and B901\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eSpecified standard\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eASTM B230, ASTM B231, ASTM B400, ASTM B901, ICEA S-76-474\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Electrical\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eGeometric mean radius (GMR)\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.197 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eInductive reactance calculation assumptions\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eNeutral assumed to carry current; phase spacing assumes cables are touching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eInductive reactance at 60 Hz\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.041 Ω\/1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eMaximum phase-to-phase use voltage\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e600 or less V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003ePhase-conductor AC resistance at 75°C\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.105 Ω\/1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003ePhase-conductor DC resistance at 25°C\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.084 Ω\/1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eDC resistance calculation note\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eIncludes a 1% length factor for plexing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Construction\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eStrand-count qualification\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eActual strand count may differ for single-input-wire construction per ASTM B901\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eInsulation material\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eCross-linked polyethylene (XLPE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003ePublished phase strand count\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e18 strands\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003ePublished neutral strand configuration\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e6\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eListed phase strand count\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e18 listed; actual strand count may differ for single-input-wire construction under ASTM B901 strands\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eListed neutral strand configuration\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e6\/1 listed; actual strand count may differ for single-input-wire construction under ASTM B901\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor stranding and grade\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eStranded, compressed 1350-H19 construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eNominal phase insulation thickness\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e60 mil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eMessenger construction\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eACSR neutral messenger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003ePhase conductor construction\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eStranded, compressed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Operating Conditions\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eMaximum conductor temperature\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e90 °C\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Applications\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eTypical applications\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e120 V overhead service for street lighting, outdoor lighting, and temporary service for construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eIntended application\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e120 V overhead service; street lighting, outdoor lighting, and temporary service for construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003c!-- registry-additional-specifications:end --\u003e","brand":"Southwire","offers":[{"title":"Per ft","offer_id":68229755666543,"sku":"ZUZARA","price":4.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8970\/4303\/files\/excel-sku-zuzara-c209c21b.jpg?v=1794011071","url":"https:\/\/excel-lighting-electrical-supply-co.myshopify.com\/products\/southwire-4-0-4-0-4-0-triplex-cable","provider":"Excel Lighting \u0026 Electrical Supply, Co.","version":"1.0","type":"link"}