{"product_id":"southwire-12-2-mc-hospital-grade-stranded-cable","title":"Southwire 12\/2 MC Hospital Grade Stranded Cable","description":"\u003cp\u003eSouthwire 12\/2 MC Hospital Grade Stranded Cable\u003c\/p\u003e\u003c!-- registry-additional-specifications:start --\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eAdditional specifications\u003c\/h2\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Installation\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eMinimum bend radius\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e3.7 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eHazardous-location suitability\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eClass I Division 2; Class II Division 2; Class III Division 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003ePatient-care installation conditions\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eInstall patient-care branch circuits per NEC Articles 517 and 330, with mechanical protection per Article 300.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Construction\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor strand count\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e19 strands\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eRedundant grounding path\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eBare 8000 series aluminum grounding\/bonding conductor and armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eBinder material\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eMylar tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eArmor construction\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eGreen aluminum interlocked armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eEquipment grounding\/bonding conductor\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eFull-sized aluminum equipment grounding\/bonding conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eInsulated ground construction\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eGreen-insulated PVC with nylon sheath, THHN\/THWN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003ePhase conductor insulation\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003ePolyvinyl chloride with nylon sheath, THHN\/THWN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Compatibility\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eCompatible fittings\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eUL-listed MCI-A fittings\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Compliance\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eEnvironmental directive\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eRoHS-2, European Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eMetal-clad cable standard\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eUL 1569 — Metal-Clad Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eFirestop-system use listing\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eListed for UL 1-, 2-, and 3-hour through-penetration firestop systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eInsulated-wire standard\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eUL 83 — Thermoplastic Insulated Wires and Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Electrical\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eAC resistance at 75°C\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e2.063 Ω\/1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eUL-listed voltage rating\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eDC resistance at 25°C\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e1.662 Ω\/1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eInductive reactance at 60 Hz\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.054 Ω\/1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eVoltage designation in product title\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e120\/208 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Operating conditions\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eTHHN\/THWN dry temperature rating\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e90 °C (dry)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Safety\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eUse restriction\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eUse is prohibited in hazardous anesthetizing areas\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Fire performance\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eFT4 vertical-tray fire tests\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eUL 1685 FT4 and IEEE 1202 FT4; IEEE test specified at 70,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eFlame rating\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eVW1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003c!-- registry-additional-specifications:end --\u003e","brand":"Southwire","offers":[{"title":"Per ft","offer_id":68229770248303,"sku":"12-2 MC STR HCF-FT","price":2.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8970\/4303\/files\/excel-sku-12-2-mc-str-hcf-ft-9519545d.jpg?v=1794011351","url":"https:\/\/excel-lighting-electrical-supply-co.myshopify.com\/products\/southwire-12-2-mc-hospital-grade-stranded-cable","provider":"Excel Lighting \u0026 Electrical Supply, Co.","version":"1.0","type":"link"}