{"product_id":"nvent-caddy-4z34-multi-function-clip","title":"nVent CADDY 4Z34 Multi-Function Clip","description":"\u003cdiv style=\"max-width:1120px;margin:0 auto;color:#374151;font-family:inherit;line-height:1.6;\"\u003e\n\u003csection style=\"padding:22px 24px;border:1px solid #E5E7EB;border-top:5px solid #DC0224;border-radius:14px;background:linear-gradient(135deg,#FFFFFF 0%,#F7F7F7 100%);box-shadow:0 4px 14px rgba(17,24,39,0.07);\"\u003e\u003cp style=\"margin:0 0 8px;color:#DC0224;font-size:0.78rem;line-height:1.3;font-weight:800;letter-spacing:0.08em;text-transform:uppercase;\"\u003eExcel Lighting \u0026amp; Electrical Supply Co.\u003c\/p\u003e\n\u003ch2 style=\"margin:0 0 10px;color:#1F2937;font-size:1.35rem;line-height:1.3;font-weight:750;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:1rem;line-height:1.7;\"\u003eThe nVent CADDY 4Z34 is a spring-steel multi-function clip with a CADDY Armour finish, specified for 1\/4–3\/8-inch rod, #12–#8 wire, and 1\/8–7\/16-inch flange. Its static ratings are 25 lb in F1 on horizontal flange only and 20 lb in F2; on 3\/8-inch smooth rod in the F2 direction, the rating is 12.5 lb.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(220px,1fr));gap:14px;\"\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eRod Size Range\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eSpecified for 1\/4–3\/8-inch rod.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eWire Size Range\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eSpecified for #12–#8 wire.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eFlange Range\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eSpecified for 1\/8–7\/16-inch flange.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eStatic Load Ratings\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eRated 25 lb in F1 on horizontal flange only and 20 lb in F2. On 3\/8-inch smooth rod in the F2 direction, the rating is 12.5 lb.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eSpring Steel and CADDY Armour\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eMade from spring steel with a CADDY Armour coating at a stated minimum thickness of 12 µm.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003e1\/4-Inch Hole; No Screw Included\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eSpecified for a 1\/4-inch hole; no screw is included.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eOverall Width\/Diameter (mm)\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e19.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eMetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eUL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eMade in USA\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;padding:20px;border:1px solid #E5E7EB;border-left:4px solid #DC0224;border-radius:12px;background:#F9FAFB;\"\u003e\u003ch2 style=\"margin:0 0 12px;color:#1F2937;font-size:1.2rem;line-height:1.3;font-weight:700;\"\u003ePractical Applications\u003c\/h2\u003e\n\u003cul style=\"margin:0;padding-left:20px;color:#4B5563;font-size:0.95rem;line-height:1.55;\"\u003e\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eLow-voltage communication cable support\u003c\/li\u003e\u003c\/ul\u003e\u003c\/section\u003e\n\u003c\/div\u003e\u003c!-- registry-additional-specifications:start --\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eAdditional specifications\u003c\/h2\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Compliance\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eTechnical Assessment Scope and Validity\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e4Z34 is listed under ITB-KOT-2019\/0889 edition 2; stated validity date 17 December 2030\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Load Conditions\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eDynamic Load Limitation\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eStatic ratings do not account for dynamic loading such as wind, water or seismic loads, unless otherwise noted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eStatic Rating Application\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eFor low-voltage communication cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Construction\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eProtective Coating\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eCADDY Armour; minimum thickness 12 µm\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Installation\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eDrop-Wire\/Rod Note\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eMay require a dedicated drop wire\/rod; consult the local code authority\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eInstallation Sequence\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eSqueeze the fastener, connect the top edge over the rod\/wire, then twist into place and release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Load Rating\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eCalculated Load Capacity\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.10 kN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eF1 Static Load Rating\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e25 [111]; horizontal flange only lb [N]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eDesign Capacity Safety Factor\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e3.0 (used for calculated load capacities)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eF2 Static Load Rating\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e20 [90] lb [N]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eF2 Rating on 3\/8-in. Smooth Rod\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e12.5 [55] on 3\/8-in. smooth rod in the F2 direction; not listed for flexible conduit, tubing or cable lb [N]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003c!-- registry-additional-specifications:end --\u003e","brand":"nVent CADDY","offers":[{"title":"Default Title","offer_id":68229761695855,"sku":"4Z34","price":1.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8970\/4303\/files\/excel-sku-4z34-6f5d60fc.jpg?v=1794011193","url":"https:\/\/excel-lighting-electrical-supply-co.myshopify.com\/products\/nvent-caddy-4z34-multi-function-clip","provider":"Excel Lighting \u0026 Electrical Supply, Co.","version":"1.0","type":"link"}