{"title":"Southwire","description":"\u003cp\u003eWorking with a Southwire specification or material list? Send it to Excel for product guidance and a quote request.\u003c\/p\u003e\u003cp\u003eInclude the part number, sizes or other required specifications, quantities and when you need the materials.\u003c\/p\u003e","products":[{"product_id":"southwire-simpull-4-awg-stranded-aluminum-xhhw-2-rw90-building-wire-green-cut","title":"Southwire SIMpull 4 AWG Stranded Aluminum XHHW-2\/RW90 Building Wire, Green, Cut","description":"\u003cdiv style=\"max-width:1120px;margin:0 auto;color:#374151;font-family:inherit;line-height:1.6;\"\u003e\n\u003csection style=\"padding:22px 24px;border:1px solid #E5E7EB;border-top:5px solid #DC0224;border-radius:14px;background:linear-gradient(135deg,#FFFFFF 0%,#F7F7F7 100%);box-shadow:0 4px 14px rgba(17,24,39,0.07);\"\u003e\u003cp style=\"margin:0 0 8px;color:#DC0224;font-size:0.78rem;line-height:1.3;font-weight:800;letter-spacing:0.08em;text-transform:uppercase;\"\u003eExcel Lighting \u0026amp; Electrical Supply Co.\u003c\/p\u003e\n\u003ch2 style=\"margin:0 0 10px;color:#1F2937;font-size:1.35rem;line-height:1.3;font-weight:750;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:1rem;line-height:1.7;\"\u003eSouthwire SIMpull 4 AWG stranded aluminum XHHW-2\/RW90 building wire has green XLPE insulation and is rated 1000 V and 90°C wet\/dry. Its 7-strand aluminum-alloy conductor has listed current ratings of 75 A at 90°C and 65 A at 75°C.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(220px,1fr));gap:14px;\"\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003e4 AWG 7-Strand Aluminum Conductor\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe conductor is 4 AWG aluminum alloy with seven strands.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eXHHW-2\/RW90 Building Wire\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe product is identified as XHHW-2\/RW90 building wire.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003e1000 V Voltage Rating\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe listed voltage rating is 1000 V.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003e90°C Wet\/Dry Rating\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe listed temperature rating is 90°C for wet and dry conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAmpacity by Temperature\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eCurrent ratings are 75 A at 90°C and 65 A at 75°C.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eGreen XLPE Insulation\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe insulation is green cross-linked polyethylene.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eApproval\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eUL; UL 44 text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor Material\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eAluminum Alloy text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor Size\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e4 AWG AWG\/kcmil (text enum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eCurrent Rating\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e75 A at 90 °C (65 A at 75 °C) A by conductor-temperature rating (structured text; integer ampere values)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eInsulation Color\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eGreen text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eInsulation Material\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eCross-Linked Polyethylene text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eOuter Diameter\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e309 mil mil (0.001 in; integer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003ePackage Type\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eCoil text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eStranding\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e7 strands count (integer strands)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eTemperature Rating\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e90 Deg C (Wet\/Dry) °C with environment qualifier (text enum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eXHHW-2 text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e1000 V V (volts; integer; AC\/DC unspecified)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;padding:20px;border:1px solid #E5E7EB;border-left:4px solid #DC0224;border-radius:12px;background:#F9FAFB;\"\u003e\u003ch2 style=\"margin:0 0 12px;color:#1F2937;font-size:1.2rem;line-height:1.3;font-weight:700;\"\u003ePractical Applications\u003c\/h2\u003e\n\u003cul style=\"margin:0;padding-left:20px;color:#4B5563;font-size:0.95rem;line-height:1.55;\"\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eCommercial service, feeder, and branch circuits\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eIndustrial conduit and cable-tray circuits\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eHealthcare wiring with specified dielectric constant ≤3.5\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003c\/div\u003e\u003c!-- registry-additional-specifications:start --\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eAdditional specifications\u003c\/h2\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Application \u0026amp; Features\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eAdditional compliance references\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eFederal Specification A-A-59544; NOM-ANCE XHHW-2 90 °C; NEC\/NFPA 70; RoHS\/REACH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eInstallation\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eCan be installed without applying pulling lubricant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eGas and oil resistance\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eGas and oil resistant II; all sizes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eApplication\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003ePrimarily for conduit and cable trays serving service, feeder, and branch circuits in commercial or industrial applications per NEC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eHealthcare-facility suitability\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eSuitable for healthcare facilities under NEC 517.160 where dielectric constant of 3.5 or less is specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Construction\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor construction\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eClass B compact-stranded bare aluminum per ASTM B800 and B801, or compact aluminum SIW per ASTM B836\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eInsulation performance\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eFlame-retardant and moisture-resistant thermoset insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Table 2 - Electrical and Engineering Data\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eAC resistance at 75 °C\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.510 Ω\/1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eMaximum pull tension\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e250 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eDC resistance at 25 °C\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.424 Ω\/1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eInductive reactance\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.048 Ω\/1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eMinimum bend radius\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e1.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Product overview\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor alloy grade\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eAlumaFlex aluminum alloy AA-8176\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Standards \u0026amp; References\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eAdditional standards\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eASTM B800; ASTM B801; ASTM B836; CSA C22.2 No. 38; ICEA S-95-658 (NEMA WC70); NMX-J-451-ANCE; NOM-063-SCFI\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003c!-- registry-additional-specifications:end --\u003e","brand":"Southwire","offers":[{"title":"Default Title","offer_id":54375755776111,"sku":"4AL XHHW-STR-GRN-FT","price":0.67,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8970\/4303\/files\/excel-sku-4al-xhhw-str-grn-ft-1fc135ee.jpg?v=1790196819"},{"product_id":"southwire-simpull-700-kcmil-aluminum-thhn-thwn-2-single-conductor-building-wire-black","title":"Southwire SIMpull 700 KCMIL Aluminum THHN\/THWN-2 Single-Conductor Building Wire, Black","description":"\u003cdiv style=\"max-width:1120px;margin:0 auto;color:#374151;font-family:inherit;line-height:1.6;\"\u003e\n\u003csection style=\"padding:22px 24px;border:1px solid #E5E7EB;border-top:5px solid #DC0224;border-radius:14px;background:linear-gradient(135deg,#FFFFFF 0%,#F7F7F7 100%);box-shadow:0 4px 14px rgba(17,24,39,0.07);\"\u003e\u003cp style=\"margin:0 0 8px;color:#DC0224;font-size:0.78rem;line-height:1.3;font-weight:800;letter-spacing:0.08em;text-transform:uppercase;\"\u003eExcel Lighting \u0026amp; Electrical Supply Co.\u003c\/p\u003e\n\u003ch2 style=\"margin:0 0 10px;color:#1F2937;font-size:1.35rem;line-height:1.3;font-weight:750;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:1rem;line-height:1.7;\"\u003eSouthwire SIMpull 700 KCMIL THHN\/THWN-2 is a single-conductor aluminum building wire with black PVC insulation and a 600 V rating. It is temperature-rated 90°C dry\/wet and 75°C in oil; specified uses include service, feeder, and branch-circuit wiring in conduit or cable trays.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(220px,1fr));gap:14px;\"\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003e700 KCMIL single conductor\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe product is specified as one 700 KCMIL conductor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAA-8176 aluminum alloy\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe conductor is 8000-series aluminum alloy, identified as AA-8176.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eBlack PVC THHN\/THWN-2 insulation\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe insulation is black PVC, and the wire type is THHN\/THWN-2.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003e600 V rating\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eRated 600 V.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eCurrent and temperature ratings\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eCurrent ratings are 375 A at 75°C and 425 A at 90°C; temperature ratings are 90°C dry\/wet and 75°C in oil.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eUL 83 approval\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe approval specification lists UL and UL 83.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eApproval\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eUL; UL 83 text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor Material\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eAluminum Alloy text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor Size\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e700 KCMIL AWG\/kcmil (text enum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eCurrent Rating\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e375 A at 75 °C; 425 A at 90 °C A by conductor-temperature rating (structured text; integer ampere values)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eInsulation Color\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eBlack text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eInsulation Material\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003ePolyvinyl Chloride (PVC) text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eOuter Diameter\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e1041 mil mil (0.001 in; integer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003ePackage Type\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eReel text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eStranding\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e58 strands count (integer strands)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eTemperature Rating\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e90 Deg C (Dry\/Wet), 75 Deg C (Oil) °C with environment qualifier (text enum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eTHHN\/THWN-2 text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e600 V V (volts; integer; AC\/DC unspecified)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;padding:20px;border:1px solid #E5E7EB;border-left:4px solid #DC0224;border-radius:12px;background:#F9FAFB;\"\u003e\u003ch2 style=\"margin:0 0 12px;color:#1F2937;font-size:1.2rem;line-height:1.3;font-weight:700;\"\u003ePractical Applications\u003c\/h2\u003e\n\u003cul style=\"margin:0;padding-left:20px;color:#4B5563;font-size:0.95rem;line-height:1.55;\"\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eService wiring in conduit or cable trays\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eFeeder wiring in conduit or cable trays\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eBranch-circuit wiring in conduit or cable trays\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003c\/div\u003e\u003c!-- registry-additional-specifications:start --\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eAdditional specifications\u003c\/h2\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Specifications\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eAdditional standards\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eASTM B800; ASTM B801; ASTM B836; CSA C22.2 No. 75; Federal Specification A-A-59544\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eJacket thickness\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e10 mils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eDiameter over conductor\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.877 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eInsulation thickness\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e70 mils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor count\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e1 conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Table 2 – Electrical and Engineering Data\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eMinimum bending radius\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e5.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eAC resistance at 75 °C\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.033 Ω\/1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eDC resistance at 25 °C\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.025 Ω\/1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eInductive reactance at 60 Hz\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.038 Ω\/1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eMaximum pull tension\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e4200 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Application\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003ePulling lubricant requirement\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eDesigned for installation without pulling lubricant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003ePrimary installation applications\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eConduit and cable trays for services, feeders, and branch circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Construction and standards\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor alloy\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eAA-8176; 8000-series aluminum alloy\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Application \u0026amp; Features\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eEnvironmental and flame ratings\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eSunlight resistant for sizes #2 and larger; Oil and Gasoline Resistant II; CT use for sizes 1\/0 AWG and larger; VW-1 and FT1 for all sizes\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Construction\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eJacket material\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eNylon SIMpull sheath\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor construction\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eClass B compact stranded bare aluminum per ASTM B800\/B801, or SIW compact aluminum per ASTM B836\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003c!-- registry-additional-specifications:end --\u003e","brand":"Southwire","offers":[{"title":"Default Title","offer_id":67627203100783,"sku":"700MCM-THHN-AL-BLK-FT","price":6.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8970\/4303\/files\/excel-sku-700mcm-thhn-al-blk-ft-9aa68ffd.jpg?v=1790878995"},{"product_id":"southwire-6-awg-7-strand-soft-drawn-bare-copper-wire-315ft-spool","title":"Southwire 6 AWG 7-Strand Soft-Drawn Bare Copper Wire, 315ft Spool","description":"\u003cdiv style=\"max-width:1120px;margin:0 auto;color:#374151;font-family:inherit;line-height:1.6;\"\u003e\n\u003csection style=\"padding:22px 24px;border:1px solid #E5E7EB;border-top:5px solid #DC0224;border-radius:14px;background:linear-gradient(135deg,#FFFFFF 0%,#F7F7F7 100%);box-shadow:0 4px 14px rgba(17,24,39,0.07);\"\u003e\u003cp style=\"margin:0 0 8px;color:#DC0224;font-size:0.78rem;line-height:1.3;font-weight:800;letter-spacing:0.08em;text-transform:uppercase;\"\u003eExcel Lighting \u0026amp; Electrical Supply Co.\u003c\/p\u003e\n\u003ch2 style=\"margin:0 0 10px;color:#1F2937;font-size:1.35rem;line-height:1.3;font-weight:750;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:1rem;line-height:1.7;\"\u003eSouthwire 6 AWG, seven-strand soft-drawn bare copper wire is supplied as a 315 ft pre-cut spool. Its listed applications include uninsulated hook-ups, jumpers, and grounds in electrical construction.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(220px,1fr));gap:14px;\"\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003e6 AWG conductor\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe wire is specified as 6 AWG.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eBare copper conductor\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe conductor is bare copper.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eSeven-strand construction\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe stranded conductor contains seven strands.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eSoft-drawn temper\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe copper temper is specified as soft-drawn (SD).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003e315 ft pre-cut spool\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eSupplied as a pre-cut 315 ft length on a spool.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eClass B stranding\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe conductor's strand class is listed as Class B.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eWire Gauge\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e6\/1 retailer Wire Gauge composite token (text enum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eStranded or Solid\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eStranded text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eTotal Wire Length (ft.)\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e315 ft (feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eWire Cut Type\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003ePre-Cut Length text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eFeatures\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eNo Features text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor Material\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eCopper text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eWeight (lb.)\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e25.515 lb (pounds)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;padding:20px;border:1px solid #E5E7EB;border-left:4px solid #DC0224;border-radius:12px;background:#F9FAFB;\"\u003e\u003ch2 style=\"margin:0 0 12px;color:#1F2937;font-size:1.2rem;line-height:1.3;font-weight:700;\"\u003ePractical Applications\u003c\/h2\u003e\n\u003cul style=\"margin:0;padding-left:20px;color:#4B5563;font-size:0.95rem;line-height:1.55;\"\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eUninsulated hook-ups in electrical construction\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eJumpers in electrical construction\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eGrounds in electrical construction\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003c\/div\u003e\u003c!-- registry-additional-specifications:start --\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eAdditional specifications\u003c\/h2\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Product specifications\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eCopper temper\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eSoft-drawn (SD)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Specifications\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor cross-sectional area\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e26,240 cmil (16.93 mm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eDC resistance at 25 °C\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.411 Ω\/1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eStrand class\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eClass B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eIndividual strand diameter\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e61 mil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eRated strength, soft-drawn\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e794 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor strand count\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e7 strands\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eApproximate conductor outside diameter\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.177 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Applications\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eApplication suitability\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eSuitable for uninsulated hook-ups, jumpers, and grounds in electrical construction\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Standards \u0026amp; References\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eApplicable ASTM standards\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eASTM B3; ASTM B8\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Construction\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor material\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eBare copper\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003c!-- registry-additional-specifications:end --\u003e","brand":"Southwire","offers":[{"title":"Default Title","offer_id":67627598348399,"sku":"6 BARE 315FT","price":339.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8970\/4303\/files\/excel-sku-6-bare-315ft-929653b2.jpg?v=1790888270"},{"product_id":"southwire-3-0-awg-bare-copper-wire-19-strand-combination-unilay-1-000ft-reel","title":"Southwire 3\/0 AWG Bare Copper Wire, 19-Strand Combination\/Unilay, 1,000ft Reel","description":"\u003cdiv style=\"max-width:1120px;margin:0 auto;color:#374151;font-family:inherit;line-height:1.6;\"\u003e\n\u003csection style=\"padding:22px 24px;border:1px solid #E5E7EB;border-top:5px solid #DC0224;border-radius:14px;background:linear-gradient(135deg,#FFFFFF 0%,#F7F7F7 100%);box-shadow:0 4px 14px rgba(17,24,39,0.07);\"\u003e\u003cp style=\"margin:0 0 8px;color:#DC0224;font-size:0.78rem;line-height:1.3;font-weight:800;letter-spacing:0.08em;text-transform:uppercase;\"\u003eExcel Lighting \u0026amp; Electrical Supply Co.\u003c\/p\u003e\n\u003ch2 style=\"margin:0 0 10px;color:#1F2937;font-size:1.35rem;line-height:1.3;font-weight:750;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:1rem;line-height:1.7;\"\u003eSouthwire 3\/0 AWG bare copper wire is a 19-strand combination-unilay, soft-drawn conductor supplied on a 1,000 ft reel. Manufacturer data lists uninsulated hook-ups, jumpers, and grounds in electrical construction as applications.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(220px,1fr));gap:14px;\"\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003e3\/0 AWG conductor\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe product is identified as 3\/0 AWG.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eBare copper wire\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe conductor is copper and is supplied in bare, uninsulated form.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003e19-strand combination-unilay construction\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe single conductor uses 19 strands in a combination-unilay configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eSoft-drawn copper temper\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe conductor is specified as soft-drawn (SD).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003e1,000 ft reel\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe stated 1,000 ft wire length is supplied on a reel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eDC resistance at 20 °C\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eSouthwire data gives 0.06431 Ω per 1,000 ft for soft-drawn copper at 20 °C.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eWire Gauge\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e000\/1 retailer Wire Gauge composite token (text enum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor Material\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eCopper text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eStranded or Solid\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eStranded text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eTotal Wire Length (ft.)\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e1000 ft (feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eWire Cut Type\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003ePre-Cut Length text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eFeatures\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eNo Features text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eWeight (lb.)\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e520 lb (pounds)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;padding:20px;border:1px solid #E5E7EB;border-left:4px solid #DC0224;border-radius:12px;background:#F9FAFB;\"\u003e\u003ch2 style=\"margin:0 0 12px;color:#1F2937;font-size:1.2rem;line-height:1.3;font-weight:700;\"\u003ePractical Applications\u003c\/h2\u003e\n\u003cul style=\"margin:0;padding-left:20px;color:#4B5563;font-size:0.95rem;line-height:1.55;\"\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eUninsulated hook-ups in electrical construction\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eJumpers in electrical construction\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eGrounding in electrical construction\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003c\/div\u003e\u003c!-- registry-additional-specifications:start --\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eAdditional specifications\u003c\/h2\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Electrical\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eAllowable ampacity\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e410 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eDC resistance, soft-drawn at 20 °C\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.06431 Ω\/1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Construction\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eStrand count\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e19 strands\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eNumber of conductors\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e1 conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor construction and temper\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eCombination-unilay; soft-drawn (SD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor material\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eCopper (CU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eStranding class\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Compliance\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eApplicable conductor standards\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eASTM B3 (soft or annealed copper wire); ASTM B787 (19-wire combination unilay-stranded soft copper wire)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Mechanical\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eRated strength, soft-drawn\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e4819 (interpolated) lb\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Application\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eApplications\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eSuitable for uninsulated hook-ups, jumpers, and grounds in electrical construction\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003c!-- registry-additional-specifications:end --\u003e","brand":"Southwire","offers":[{"title":"Default Title","offer_id":67627604410479,"sku":"3\/0 STR BARE","price":4.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8970\/4303\/files\/excel-sku-3-0-str-bare-d0155d98.jpg?v=1790888287"},{"product_id":"southwire-4-awg-7-strand-bare-copper-wire-200ft-spool","title":"Southwire 4 AWG 7-Strand Bare Copper Wire, 200ft Spool","description":"\u003cdiv style=\"max-width:1120px;margin:0 auto;color:#374151;font-family:inherit;line-height:1.6;\"\u003e\n\u003csection style=\"padding:22px 24px;border:1px solid #E5E7EB;border-top:5px solid #DC0224;border-radius:14px;background:linear-gradient(135deg,#FFFFFF 0%,#F7F7F7 100%);box-shadow:0 4px 14px rgba(17,24,39,0.07);\"\u003e\u003cp style=\"margin:0 0 8px;color:#DC0224;font-size:0.78rem;line-height:1.3;font-weight:800;letter-spacing:0.08em;text-transform:uppercase;\"\u003eExcel Lighting \u0026amp; Electrical Supply Co.\u003c\/p\u003e\n\u003ch2 style=\"margin:0 0 10px;color:#1F2937;font-size:1.35rem;line-height:1.3;font-weight:750;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:1rem;line-height:1.7;\"\u003eSouthwire's 4 AWG, seven-strand bare copper wire is soft-drawn and classified as Class B. It is supplied on a 200 ft pre-cut spool for uses that include grounding, uninsulated connections and jumpers, and as a conductor in insulated cable for general wiring and underground systems.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(220px,1fr));gap:14px;\"\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003e4 AWG Bare Copper\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe product is bare copper wire in 4 AWG size.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eSeven-Strand Class B Construction\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe conductor has seven strands and a Class B classification.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003e200 ft Pre-Cut Spool\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eIt is supplied in a pre-cut 200 ft length on a spool.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eSoft-Drawn Copper\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe copper temper is specified as soft-drawn.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003e100% IACS Copper Conductivity\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eListed conductivity is 100% IACS at 20°C.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eASTM B3 and B8 References\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eSpecifications reference ASTM B3 for soft or annealed copper wire and ASTM B8 for concentric-lay-stranded copper conductors.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eWire Gauge\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e4\/1 retailer Wire Gauge composite token (text enum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eStranded or Solid\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eStranded text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eTotal Wire Length (ft.)\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e200 ft (feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eWire Cut Type\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003ePre-Cut Length text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eFeatures\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eNo Features text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor Material\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eCopper text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eWeight (lb.)\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e25.6 lb (pounds)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;padding:20px;border:1px solid #E5E7EB;border-left:4px solid #DC0224;border-radius:12px;background:#F9FAFB;\"\u003e\u003ch2 style=\"margin:0 0 12px;color:#1F2937;font-size:1.2rem;line-height:1.3;font-weight:700;\"\u003ePractical Applications\u003c\/h2\u003e\n\u003cul style=\"margin:0;padding-left:20px;color:#4B5563;font-size:0.95rem;line-height:1.55;\"\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eGrounding conductors\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eUninsulated connections and jumpers\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eConductor in insulated cable for general wiring and underground systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003c\/div\u003e\u003c!-- registry-additional-specifications:start --\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eAdditional specifications\u003c\/h2\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Standards \u0026amp; References\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eApplicable standards\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eASTM B3 (soft or annealed copper wire); ASTM B8 (concentric-lay-stranded copper conductors)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Applications and Features\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eCopper material properties\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eElectrolytic Tough Pitch copper, UNS C11000; at least 99.9% copper purity; soft-drawn copper conductivity of 100% IACS at 20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eSuitable applications\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eClass B and C flexible stranded designs are suitable for uninsulated connections, jumpers, grounding, and insulated cable use in general wiring and underground systems.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Bare Copper Wire and Cable specifications\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eAllowable ampacity\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e170 A (75°C conductor temperature, 25°C ambient temperature, 2 ft\/s wind in sun)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Specifications\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eStrand class\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eClass B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eApproximate conductor weight per length\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e128 lb\/1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor strand count\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e7 strands\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Table 1 – Physical and Electrical Data\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eRated strength\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e333 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eDC resistance\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.258 Ω\/1000 ft at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eApproximate conductor outside diameter\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.225 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor cross-sectional area\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e41,740 cmil (26.93 mm²) cmil; mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eAC resistance\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e0.310 Ω\/1000 ft at 75 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Product description\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eCopper temper\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eSoft-drawn copper\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003c!-- registry-additional-specifications:end --\u003e","brand":"Southwire","offers":[{"title":"Default Title","offer_id":67627608735855,"sku":"4BARE STR SPOOL-200FT","price":349.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8970\/4303\/files\/excel-sku-4bare-str-spool-200ft-929653b2.jpg?v=1790888311"},{"product_id":"southwire-bare-stranded-copper-wire","title":"Southwire Bare Stranded Copper Wire","description":"\u003cdiv style=\"max-width:1120px;margin:0 auto;color:#374151;font-family:inherit;line-height:1.6;\"\u003e\n\u003csection style=\"padding:22px 24px;border:1px solid #E5E7EB;border-top:5px solid #DC0224;border-radius:14px;background:linear-gradient(135deg,#FFFFFF 0%,#F7F7F7 100%);box-shadow:0 4px 14px rgba(17,24,39,0.07);\"\u003e\u003cp style=\"margin:0 0 8px;color:#DC0224;font-size:0.78rem;line-height:1.3;font-weight:800;letter-spacing:0.08em;text-transform:uppercase;\"\u003eExcel Lighting \u0026amp; Electrical Supply Co.\u003c\/p\u003e\n\u003ch2 style=\"margin:0 0 10px;color:#1F2937;font-size:1.35rem;line-height:1.3;font-weight:750;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:1rem;line-height:1.7;\"\u003eSouthwire's bare stranded copper wire is specified as a 1,000 ft pre-cut length with one 19-strand conductor. Listed applications include uninsulated hook-ups, jumpers, and grounds in electrical and substation construction.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(220px,1fr));gap:14px;\"\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eBare stranded copper wire\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe product is listed as bare, stranded copper wire.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003e1,000 ft pre-cut length\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe specified total wire length is 1,000 ft, with the cut type listed as pre-cut.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eSingle 19-strand conductor\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eSpecifications list one conductor made up of 19 strands.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eCombination-unilay, soft-drawn temper\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe conductor is specified as combination-unilay and soft-drawn (annealed).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eUL approval\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe product specifications list it as UL approved.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eASTM B-3 and B-787\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe listed applicable ASTM standards are ASTM B-3 and ASTM B-787.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor Material\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eCopper text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eWire Gauge\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e000\/1 retailer Wire Gauge composite token (text enum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eStranded or Solid\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eStranded text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eTotal Wire Length (ft.)\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e1000 ft (feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eWire Cut Type\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003ePre-Cut Length text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eFeatures\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eNo Features text enum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;padding:20px;border:1px solid #E5E7EB;border-left:4px solid #DC0224;border-radius:12px;background:#F9FAFB;\"\u003e\u003ch2 style=\"margin:0 0 12px;color:#1F2937;font-size:1.2rem;line-height:1.3;font-weight:700;\"\u003ePractical Applications\u003c\/h2\u003e\n\u003cul style=\"margin:0;padding-left:20px;color:#4B5563;font-size:0.95rem;line-height:1.55;\"\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eUninsulated electrical hook-ups\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eJumpers in electrical construction\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eGrounds in substation construction\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003c\/div\u003e\u003c!-- registry-additional-specifications:start --\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eAdditional specifications\u003c\/h2\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Compliance\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eUL approval\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eUL approved\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Conductor specifications\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor count\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e1 conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eStrand count\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e19 strands\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Meets or exceeds\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eApplicable ASTM standards\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eASTM B-3; ASTM B-787\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Applications\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eApplication\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eUninsulated hook-ups, jumpers, and grounds in electrical and substation construction\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Material\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor material\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · Construction\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor construction and temper\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eCombination-unilay, soft-drawn (annealed)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003c!-- registry-additional-specifications:end --\u003e","brand":"Southwire","offers":[{"title":"Default Title","offer_id":67627610079343,"sku":"3\/0 BARE","price":5.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8970\/4303\/files\/excel-sku-3-0-bare-aadb9972.jpg?v=1790888335"}],"url":"https:\/\/excel-lighting-electrical-supply-co.myshopify.com\/collections\/southwire.oembed","provider":"Excel Lighting \u0026 Electrical Supply, Co.","version":"1.0","type":"link"}